Heating and cooling

Heating and cooling problems

Caution — power off first

The checks on this page are safe; deeper diagnosis is not. Each symptom page carries its own verdict.

Start with the two safe checks: the air filter and the circuit breaker. If you smell gas or a carbon monoxide alarm sounds, leave the building and call from outside. Anything involving refrigerant, gas or line voltage requires a licensed technician.

First: the two situations that are not a maintenance question

If you smell gas, or a carbon monoxide alarm is sounding, leave the building and call 911 or your gas utility from outside. Do not operate switches. Do not look for the leak. Nothing below applies until that is resolved.

The two safe checks to make first

  1. The filter. A clogged filter starves airflow and produces symptoms that look like serious failures: weak capacity, a frozen coil, strange cycling. It is the most common cause and the cheapest one.
  2. The breaker. Check the electrical panel. Reset it once. If it trips again, stop and call a technician — a breaker that trips repeatedly is doing its job.

By symptom

AC not cooling

Why a system runs but the house stays warm, and which checks are safe to do yourself.

Heat not working

No heat, lukewarm air, and the difference between a control problem and a combustion problem.

Frozen coils and ice

Ice on the indoor coil or the outdoor unit — airflow starvation versus low refrigerant charge.

Water leaks and condensate

Where the water comes from, which leaks are a safe DIY fix, and which mean stop.

Short cycling and runtime

Equipment that starts and stops too often, and what oversizing has to do with it.

Noises and smells

What each sound and smell indicates — including the two that mean leave the building.

Airflow and uneven rooms

One room too hot, weak registers, and why the ducts are usually the answer.

Thermostat issues

Blank screens, wrong readings, wiring, and settings that look like equipment failure.

What should you know about refrigerant?

Refrigerant circulates in a sealed loop. It is not consumed the way fuel or oil is, so a system that is low on charge has a leak. Adding refrigerant without finding and repairing that leak treats the symptom, vents the new charge over the following weeks, and costs you the same money again next season.

It is also regulated. Only Section 608 certified technicians may purchase refrigerants intended for use with stationary refrigeration and air-conditioning equipment. The restriction covers ozone-depleting substances and non-ozone-depleting substitutes — including HFCs — in cylinders, cans or drums. Wholesalers must record the purchaser's name, the date of sale and the quantity.

There is one exception that confuses people: small cans of refrigerant for vehicle air conditioning are still sold without certification. That exception is for cars and does not extend to the equipment in your house.

For new equipment, the 700 GWP limit in force since January 1, 2025 is why current systems ship with R-454B (GWP 465) or R-32 (GWP 675) rather than R-410A (GWP 2088). R-410A inventory built before 2025 can still be legally installed — EPA removed the installation deadline on May 21, 2026. The full timeline.

Why do the ducts matter as much as the equipment?

Equipment capacity is rated at a specific airflow. If the ducts cannot move that air, the equipment cannot deliver what its label promises, and the homeowner concludes they were oversold.

The number that reveals it is static pressure: the resistance the blower works against, measured in inches of water column. It is to a duct system roughly what blood pressure is to a person. A contractor who measures it before quoting a replacement is doing the job; one who does not is assuming your ducts are fine.

Duct design has its own ACCA standard, Manual D, and it is the step most often skipped on a replacement because the ducts already exist and reusing them costs nothing up front. What Manual D determines · ducts and airflow.

How is the right equipment size decided?

Nearly every persistent comfort problem traces back to equipment size, and size is decided before the first box arrives. The standard is the ACCA Manual J load calculation (ANSI/ACCA 2 Manual J - 2016), which totals the heat gain and loss of your specific house: orientation, window area and type, insulation levels, air infiltration, internal gains, and your local design temperature.

What a Manual J is not: square feet per ton, and not the old unit's tonnage. The first ignores everything that makes one house different from another. The second assumes whoever sized the old equipment got it right, and propagates their error for another fifteen years.

Oversized equipment reaches the setpoint and shuts off before it has dehumidified, so the house ends up cold and clammy at the same time. Every start is also the hardest moment in a compressor's life, so wear accelerates. And you pay for the surplus capacity twice — once to buy it and again to run it.

Ask for the completed Manual J in writing, not the claim that one was done. What it contains and how to read it.

What should a bid show you?

Three bids rarely quote the same job, so comparing headline price compares three different things. The one that was done properly shows its work, and you can check it line by line:

  • Model numbers for the outdoor unit, indoor coil, and air handler or furnace.
  • The AHRI reference number for that exact combination. A rating applies to a matched system, not to an outdoor unit on its own.
  • The SEER2 and, on a heat pump, the HSPF2 of that combination.
  • The Manual J result the sizing came from.
  • The measured static pressure and any duct work included.
  • The permit, and who pulls it.
  • Labour warranty, separate from parts, and whether registration is required.

The full red-flags checklist.

How can you verify any of this yourself?

Everything regulatory on this site traces to a primary source and carries the date it was read: DOE for efficiency standards, EPA for refrigerants and Section 608, the IRS for tax credits, and ACCA for load calculation. The sources for this page are listed at the end with the date each was consulted.

If you find a different figure elsewhere, check two things before deciding which to believe: whether the page says which generation its efficiency metric belongs to, and whether it carries a visible review date. Most of the outdated content in this category fails both tests.