Rheem gas furnace with a 7-segment IFC display fault codes (R801T, R802V, R801V, R92 / R95 series, Ruud Achiever equivalents)
Every fault code for this Rheem gas furnace with a 7-segment IFC display is below, with what it indicates and a verdict: whether you can safely check it or it is a call for a technician. Here the code shows on a 7-segment display. The source is Rheem's own service manual. Confirm your model is on the list; other Rheem controls use different codes.
Before any code: if you smell gas or a carbon monoxide alarm is sounding, this is not a diagnostic exercise. Leave the house and call from outside. What to do about a gas smell or a CO alarm.
How to read the display
These Rheem and Ruud furnaces show two-digit fault codes on a single 7-segment display, not a flash count. A steady "0" is standby, and a letter (C, H or F) shows the current mode — cooling, heating or continuous fan — which is normal, not a fault. A two-digit code is shown one digit at a time: the first digit for one second, then the second digit for one second, then a pause, repeating. So "22" is a 2, then a 2. Some conditions alternate two codes, such as 10 and 11 together for an ignition lockout. Ruud furnaces use the same control; confirm the code list against the label inside your furnace.
What each code means
Each code carries a safety verdict. Caution means there is a check you can safely make; pro-only means the correct repair is certified work and we do not walk through it here.
10 — One-hour lockout (soft lockout)
One-hour lockout (soft lockout)
The control has stopped trying and will wait about an hour before resuming. On its own it is the lockout state; it is usually shown alternating with the code that caused it — 11 for failed ignition, 13 for lost flame, 14 for unexpected flame — so read the companion code to know why.
What you can do: Note the other code shown with it and read that entry. You can reset once by cycling the thermostat, but a lockout that returns is telling you the underlying fault is still there.
11 — Failed ignition
Failed ignition
The furnace tried and failed to light. After four failures in a row the control enters the one-hour lockout (shown as 10 alternating with 11).
What you can do: Confirm the gas is on and the filter is clean, then reset once. If it still will not light, the igniter, flame sensor or gas supply is a technician's diagnosis.
12 — Low flame sense
Low flame sense
The flame is lit but the current the flame sensor reports is below the level the control needs. It usually means a dirty or mispositioned flame sensor.
What you can do: Cleaning a flame sensor is combustion-side work this site does not walk through. It is usually a short technician visit.
14 — Unexpected flame
Unexpected flame
The control sensed flame when there should be none. Because it can mean a gas valve that is not fully closing, it is not a wait-and-see code.
What you can do: Call a technician. If you also smell gas, leave and treat it as the emergency at the top of this page.
22 — Main or auxiliary limit open
Main or auxiliary limit open
A limit switch opened because the furnace got too hot. As with any limit trip, the leading cause is not enough air moving across the heat exchanger.
What you can do: Replace a dirty filter and open blocked vents — that is the common cause and the safe fix. If it returns with a clean filter, the limit or blower needs a technician.
26 — L1 and neutral reversed
L1 and neutral reversed
Line and neutral are reversed at the furnace, and it will not run for heat until corrected. On a newly installed or serviced furnace this points back at the wiring.
What you can do: Line-voltage wiring is for an electrician or the installer.
33 — Rollout switch open — a combustion safety trip
Rollout switch open — a combustion safety trip
The rollout switch opened, meaning burner flames were not being drawn into the heat exchanger properly and rolled back toward the burners. This is a safety trip, and the furnace locks out for a reason.
What you can do: Do not keep resetting a rollout to run the furnace. It points at a blocked heat exchanger, a venting problem or a combustion fault a technician must find first.
34 — Induced draft motor overcurrent
Induced draft motor overcurrent
The induced draft (inducer) motor is drawing more current than it should, which points at a failing motor or an obstruction in it.
What you can do: An inducer motor is a technician's diagnosis and replacement, not a homeowner part.
56 / 57 — Pressure switch open when it should be closed
Pressure switch open when it should be closed
A pressure switch did not confirm closed during operation — code 56 for the ignition switch, 57 for the combustion switch. The usual causes are a blocked vent or flue, a blocked condensate drain, or a weak inducer.
What you can do: Clear the outdoor intake and exhaust terminations of snow, leaves or a nest. The condensate drain and the inducer are a technician's diagnosis.
61 — Blower fault
Blower fault
The control expected the indoor blower to run and could not confirm it. It often appears with a limit code because a furnace that overheats from a stopped blower trips its limit.
What you can do: A blower that will not run is a technician's diagnosis. Do not keep forcing heat calls while this shows.
71 — Inducer fault
Inducer fault
The induced draft motor did not run as expected. Without the inducer establishing draft, the furnace cannot safely light.
What you can do: The inducer and its wiring are a technician's diagnosis.
93 — Control fault
Control fault
The integrated furnace control has diagnosed its own internal fault. The manual reaches this only after other causes are ruled out.
What you can do: Replacing the control is a technician's job, and a good technician confirms the other causes are ruled out first.
97 — Gas valve circuit fault
Gas valve circuit fault
The control detected a fault in the gas valve circuit. Anything involving the gas valve and its wiring is certified work.
What you can do: This is a gas-side electrical fault for a qualified technician. There is no homeowner action.
A note on brand names
We use the Rheem name only to identify which equipment these codes apply to. We are not affiliated with Rheem and are not an official support channel, and the code map above is written in our own words from the published service manual cited below.