Heating

# What is HSPF2?

HSPF2 (Heating Seasonal Performance Factor 2) measures Heat pump heating efficiency across a whole heating season. It is on the scale in force since January 1, 2023, so you can compare it directly against other figures on the same metric in current quotes. Ask for the figure in writing, with the AHRI reference number for the exact combination quoted.

    Generation
    Current
  

    Replaces
    HSPF
  

    In force since
    2023-01-01
  

  

  **Jurisdiction notice. **Efficiency standards, refrigerant rules, incentives, and licensing are set federally, by region, and by state, and they change. This page reflects DOE guidance of October 5, 2022 as of 2026-08-17. Verify before purchasing.

  
## What does HSPF2 measure?

  
HSPF2 measures how much heat a heat pump delivers over a heating season per unit of electricity consumed, on the DOE test procedure required since January 1, 2023. A higher HSPF2 means less electricity for the same heat.

  
A higher value means less energy for the same result.

  
## How is it different from HSPF?

  
**HSPF2** replaced **HSPF** for equipment manufactured on or after 2023-01-01. The difference is not the formula so much as the test bench: the current procedure measures at a higher external static pressure, much closer to what equipment meets in a real house.

  
**They are not directly comparable.**
  Although SEER2, HSPF2, and EER2 ratings are similar to ratings using the original metrics, they are not directly comparable. Compliance with the new standards for each model must be determined based on its measured SEER2, HSPF2, or EER2.

  

  
### Which generation is your number?

  
    
      Metric on the document
      
        SEER2SEER
        EER2EER
        HSPF2HSPF
        AFUE
      
    
    
      Value (optional)
      
    
  
  
    
Current metric

    
**SEER2** is on the current scale, in force since January 1, 2023.

  

  
## What is the federal minimum?

  
    Nationwide minimums in HSPF2 for units manufactured on or after 2023-01-01. Source: DOE.
    Product class
      HSPF2
    Split-system heat pumps
    7.5Single-package heat pumps
    6.7Small-duct, high-velocity systems
    6.1Space-constrained heat pumps
    6.3
  
These nationwide minimums apply by date of manufacture. The Southeast and Southwest additionally carry regional minimums for air conditioners, enforced by date of installation.
  [Standards by region](https://hvacbuddy.shop/efficiency/standards/).

  
## How do you use this when comparing bids?

  
    - Ask for the **HSPF2** figure in writing.

    - Ask for the AHRI reference number for the exact combination quoted.

    - Compare the same metric across all three bids. Never mix scales.

  
  
A rated efficiency applies to a matched system — a specific outdoor unit with a specific indoor coil and, often, a specific air handler or furnace. Pairing a new outdoor unit with a mismatched indoor unit does not deliver the rated efficiency, and in the Southeast and Southwest it may not be a legal installation at all. The AHRI reference number identifies the certified combination, and it should appear on your bid.

  
## How is the right equipment size decided?

  

Nearly every persistent comfort problem traces back to equipment size, and size
is decided before the first box arrives. The standard is the ACCA
**Manual J** load calculation
(ANSI/ACCA 2 Manual J - 2016), which totals the heat gain and loss of
your specific house: orientation, window area and type, insulation levels, air
infiltration, internal gains, and your local design temperature.

What a Manual J is *not*: square feet per ton, and not the old unit's
tonnage. The first ignores everything that makes one house different from
another. The second assumes whoever sized the old equipment got it right, and
propagates their error for another fifteen years.

Oversized equipment reaches the setpoint and shuts off before it has
dehumidified, so the house ends up cold and clammy at the same time. Every start
is also the hardest moment in a compressor's life, so wear accelerates. And you
pay for the surplus capacity twice — once to buy it and again to run it.

Ask for the completed Manual J in writing, not the claim that one was done.
[What it contains and how to read it](https://hvacbuddy.shop/sizing/manual-j/).

  
## What should a bid show you?

  

Three bids rarely quote the same job, so comparing headline price compares
three different things. The one that was done properly shows its work, and you can
check it line by line:

  - Model numbers for the outdoor unit, indoor coil, and air handler or furnace.

  - The **AHRI reference number** for that exact combination. A
  rating applies to a matched system, not to an outdoor unit on its own.

  - The SEER2 and, on a heat pump, the HSPF2 of that combination.

  - The Manual J result the sizing came from.

  - The measured static pressure and any duct work included.

  - The permit, and who pulls it.

  - Labour warranty, separate from parts, and whether registration is required.

[The full red-flags checklist](https://hvacbuddy.shop/hiring/).

  
## What actually drives the cost?

  

We publish no national average price, and the reason matters: an average across
every house, region and system type is not a number you can act on. A replacement
that includes duct modification, an electrical upgrade and a permit is a different
job from a straight swap, and both read as "system replacement" on a
one-page proposal.

What actually drives your number:

  - **Equipment capacity and tier**, which should come from the Manual J rather than the old nameplate.

  - **The ducts** — whether they can move the air the new equipment needs, and what it costs if they cannot.

  - **Electrical work**, if a circuit or panel change is required.

  - **Permit and inspection**, usually required.

  - **Refrigerant** — current equipment uses R-454B or R-32; remaining pre-2025 R-410A stock may price differently.

[What a bid should itemise](https://hvacbuddy.shop/costs/) ·
[operating cost calculator](https://hvacbuddy.shop/calculators/).

  
## Which efficiency numbers can you actually compare?

  

If you are comparing efficiency figures, check which generation they belong to
first. On January 1, 2023 DOE changed the test procedure and renamed three
metrics: SEER became **SEER2**, EER became **EER2**, and
HSPF became **HSPF2**. The current procedure measures at a higher
external static pressure, much closer to what equipment meets once installed in a
real house on real ductwork.

DOE is explicit about the consequence: "Although SEER2, HSPF2, and EER2 ratings are similar to ratings using the original metrics, they are not directly comparable. Compliance with the new standards for each model must be determined based on its measured SEER2, HSPF2, or EER2."
In practice: a SEER figure from a 2019 article cannot tell you whether a quote
reading SEER2 is good, bad or identical.

That is why we publish no conversion factor. We do not publish a SEER-to-SEER2 conversion factor. DOE states that ratings on the new metrics are "not directly comparable" to ratings on the original metrics, and that compliance must be determined from the measured SEER2, EER2 or HSPF2 value. Approximate multipliers circulate widely, but they vary by equipment type and configuration, and using one to compare an old article's number against a number on today's quote is how homeowners end up believing they were offered less efficiency than they were. Compare like with like: ask for the SEER2 figure, and check it against the AHRI certificate.

The nationwide minimum for a split-system air conditioner is
13.4 SEER2, and for a split-system heat pump
14.3 SEER2 with 7.5
HSPF2. [What each metric measures](https://hvacbuddy.shop/efficiency/) ·
[minimums by region and state](https://hvacbuddy.shop/efficiency/standards/).

  
## How can you verify any of this yourself?

  

Everything regulatory on this site traces to a primary source and carries the
date it was read: DOE for efficiency standards, EPA for refrigerants and Section
608, the IRS for tax credits, and ACCA for load calculation. The sources for this
page are listed at the end with the date each was consulted.

If you find a different figure elsewhere, check two things before deciding which
to believe: whether the page says which generation its efficiency metric belongs
to, and whether it carries a visible review date. Most of the outdated content in
this category fails both tests.

  Sources (2)
  - U.S. Department of Energy —
    [Central Air Conditioners — Conservation Standards guidance (Final, October 5, 2022)](https://www1.eere.energy.gov/buildings/appliance_standards/pdfs/2023_CAC_Standards_FAQ_10-5-2022_Final.pdf)
    (accessed 2026-08-17)

- Code of Federal Regulations —
    [10 CFR 430.32(c) — Energy conservation standards for central air conditioners and heat pumps](https://www.ecfr.gov/current/title-10/section-430.32)
    (accessed 2026-08-17)

By [HVACBuddy Editorial Team](https://hvacbuddy.shop/authors/editorial-team/).
    Last reviewed: 2026-08-18.
    
  Verified: 2026-08-17

  HVACBuddy publishes independent information. We do not install or service equipment, we do not dispatch contractors, and we do not sell leads. Nothing here is engineering, tax, or legal advice.